CVE Database
We keep a database of CVE to help our customers keep track. Enter the CVE ID for more details:
Current Major Vulnerabilities
Latest High & Critical CVEs
CVE-2024-4291 | A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4252 | A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4251 | A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4250 | A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4249 | A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4248 | A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4247 | A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4246 | A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4245 | A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
CVE-2024-4244 | A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | HIGH |
2024 · 2023 · 2022 · 2021 · 2020 · 2019 · 2018 · 2017 · 2016 · 2015 · 2014 · 2013 · 2012 · 2011 · 2010 · 2009 · 2008 · 2007 · 2006 · 2005 · 2004 · 2003 · 2002 · 2001 · 2000 · 1999 ·